Martin by HARMAN Exterior Dot-HP is a bright, outdoor-rated dot designed to create media facades or perimeter lighting on large buildings and structures for long-distance viewing. This high-performance exterior LED dot for large venues allows for long fixture runs with variable pixel pitches for flexible designs. A creative tool for lighting designers, the Exterior Dot-HP is available in two versions – RGB color mixing or cool white – with a number of front designs for a variety of unique looks. It is driven by the Martin P3 System Controller family for easy setup and video display. The Exterior Dot-HP is also compatible with RDM/DMX for smaller setups.
How processing works for LED video
- High-intensity calibrated video dot
- Rugged IP66 housing for permanent outdoor installations
- Easy setup and long cable runs for clean installation
Features
- 100 lumen per dot calibrated
- Available in clear front, diffuser dome and directional lens variants
- RGB or cold white LED engine
- Flexible mounting system allows for customized solutions
- Local integral in-built diagnostics tool
- High-quality 16-bit per color image processing technology
- Pixel-level brightness and color calibration for optimal image quality
- P3/RDM/DMX controllable (automatic protocol detection)
- Intuitive mapping and addressing via P3 System Controller
- Combined power/data input over single cable
- Supported by integrated power and data processor (P3 PowerPort 1500 or P3 PowerPort 1000 IP) and simple cabling system
Tech Specs
PhysicalDiameter: 72 mm (2.9 in.)Height with clear front: 34 mm (1.4 in.)Height with dome front: 49 mm (2 in.)Height with directional front: 43 mm (1.7 in.)Weight, clear front and dome front models: 300 g (0.7 lbs.)Weight, directional front models: 350 g (0.8 lbs.)
Control and ProgrammingControl options: Martin P3™ System Controller via Martin P3™PowerPort 1500, Martin P3™ PowerPort 1000 IP and/orRDM/DMXProtocol detection: AutomaticControl modes: RGB (RGB variants), white intensity (CWvariants), basicDMX channels: 3/10Setting and addressing: Martin P3™ System controller or RDM-compliant DMX controllerControl resolution: 16-bit (P3) or 8-bit (DMX) control of eachcolorCalibration: Color and intensity for each DotDMX compliance: USITT DMX512-ARDM compliance: ANSI/ESTA E1.20Firmware update: Via Martin P3™ System Controller
Control/User InterfaceDevice status: Multi-color visual indicationDevice test and reset: Magnetic button to call up fixture statusand test fixture
OpticsOptionsClear FrontDome frontDirectional front (TIR lens)LED manufacturer, Exterior Dot-HP RGB: OsramLED manufacturer, Exterior Dot-HP CW: SeoulMinimum LED lifetime: 50 000 hours (to >70% luminous output)**Figure obtained under manufacturer’s test conditions
Photometric DataColor resolution: 16 bits per color (48 bit per pixel)Dot pitch: 72 mm - 500 mm (center-to-center)Viewing angleClear front: 103° x 103° (half-peak)Dome front: 125° x 125° (half-peak)Directional front: 22° x 22° (half-peak)RGB DotsTotal output, calibrated modeClear front: 90 lumens, 36 cdDome front: 62 lumens, 18 cdDirectional front: 72 lumens, 270 cdTotal output, non-calibrated modeClear front: 120 lumens, 48 cdDome front: 80 lumens, 24 cdDirectional front: 96 lumens, 360 cdCool White DotsTotal output, calibrated modeClear front: 160 lumens, 62 cdDome front: 110 lumens, 32 cdDirectional front: 120 lumens, 590 cdTotal output, non-calibrated modeClear front: 210 lumens, 82 cdDome front: 142 lumens, 41 cdDirectional front: 160 lumens, 775 cd
Video ProcessingBrightness controlGamma correction and controlColor temperature controlColor space controlCalibration processingSynchronization
Signal ProtocolP3 (via Martin P3™ PowerPort) or RDM/DMX
ConstructionBase: Cast aluminumColor: Electrostatic powder-coated (custom colors available byspecial order) (custom colors available on project basis)Protection rating: IP66Impact resistance: IK05Corrosion resistance: C5-M (very high corrosivity / marine, ISO12944)RoHS compliant.
InstallationOrientation: AnyMounting points: Direct surface mount, optional mounting plateor optional mounting profile
ConnectionsPower and data input: 6-pin custom (BBD) IP66-ratedPower and data thru: 6-pin custom (BBD) IP66-ratedHot-pluggable
ElectricalNominal input voltage: 48 VDC +/- 4%Power supply options: Martin P3™ PowerPort 1500, P3™PowerPort 1000 IP, Martin™ IP66 PSU or generic 48 VDC PSUTypical total power consumption, calibrated mode: 5 W at fullintensity, full whiteTypical total power consumption, uncalibrated mode: 7 W at fullintensity, full white
ThermalCooling: ConvectionMaximum ambient temperature (Ta max.): 55° C (131° F)Minimum ambient temperature (Ta min.): -20° C (-4° F)Total heat dissipation (calculated, +/- 10%): 20 BTU/hr
ApprovalsEU safety: EN 60950-1, EN 60950-22EU EMC: EN 55024, EN 55032 (Class A), EN 61000-3-2, EN61000-3-3US safety: UL 60950-1, UL 60950-22US EMC: FCC Part 15 Class ACanadian safety: CSA C22.2 No. 60950-1, No. 60950-22Canadian EMC: ICES-003 Class AAustralia/NZ: RCM
AccesoriosHerramienta de prueba magnética, juego de 10: P / N 91610139Herrajes de montajePlaca de brida para montaje en superficie, aluminio, exteriorPunto-HP: P / N 91606020Kit de perfil de montaje incl. soporte de puntos, tornillos ycerradura, Dot-HP Exterior, 57 mm (2.25 in.): P / N 91606021Perfil de Montaje, Dot Exterior / HP Pixline, 320 mm (12.6 in.): P/ N 91611620Perfil de Montaje, Exterior Dot-HP / Pixline, 1280 mm (50.4 in): P / N 91611610Soporte de montaje depuntospara exterior Dot-HP Perfil de montaje: P/ N TBAPerfil de montaje de cerraduras, Exterior Dot-HP / Pixline,juego de 10: P / N 91611725CablesCable de alimentación + datos de entrada, XLR macho de 4pines (para P3 PowerPort 1500) a fem. BBD, 0.25 m (0.9 pies):P / N 91616046Cable de entrada de alimentación + datos, conector macho XLR+ cable de 5 pines (para PSU) a BBD hembra, 0.25 m (0.9 pies):P / N 91616048Power + Cable de entrada de datos, 5 pines macho XLR +macho Martin ™ IP66 PSU a fem. BBD, 0.25 m (0.9 pies): P / N91616050Cable de extensión Power + Data, Tipo de instalación CMX,BBD-BBD 1 m (3.3 pies): P / N 91616055Cable de extensión Power + Data, Tipo de instalación CMX,BBD -BBD, 2.5 m (8.2 pies): P / N 91616056Cable de extensión Power + Data, Tipo de instalación CMX,BBD-BBD, 5 m (16.4 ft): P / N 91616057Cable de extensión Power + Data, Tipo de instalación CMX ,BBD-BBD, 10 m (32.9 pies): P / N 91616058Cable de extensión Power + Data, Tipo de instalación CMX,BBD-BBD, 25 m (82.1 ft): P / N 91616059Cable de extensión Power + Data, Tipo de instalación CMX,sin conectores, 100 m (328.1 ft) : P / N 91616060Adaptador dederivaciónDMX, macho BBD a conector XLR hembra de 5 pines, 0.25m (0.9 pies): P / N 91616051Adaptador de alimentación + datos XLR5 + XLR4-BBD 0.25 m(0.9 pies): P / N 91616049adaptador de corriente + Data BBD-XLR4 0,25 m (0,9 ft.): P / N91616047Conectoresde alimentación + cable de datos Connector, BBD, varón: P / N91611750Power + Data cable Conector, BBD, hembra: P / N 91611751blanking tapas para conectores hembra BBD no utilizados,juego de 10: P / N 91616052
Artículos relacionadosMartin P3 ™ PowerPort 1500: P / N 90721040Martin P3 ™ PowerPort 1000 IP Instalación: P / N 90721080Martin ™ IP66 PSU 240 W fuente de alimentación externa:P / N 90760330Martin P3-050 ™ Controlador del sistema: P / N 90721090Martin controlador del sistema P3-150 ™: P / N 90721015Martin controlador del sistema P3-300 ™: P / N 90721060Martin controlador del sistema P3-PC ™: P / N 90721030
Información para hacer pedidosExterior Dot-HP RGB, Aluminio, Transparente Frente: P / N 90357683Exterior Dot-HP RGB, Aluminio, Parte delantera transparente, juego de 9: P / N 90357697Exterior Dot-HP RGB, Aluminio, Parte delantera del domo: P / N 90357685Exterior Dot-HP RGB, aluminio, domo frontal, juego de 9: P / N 90357696Exterior Dot-HP RGB, aluminio, frontal direccional (lente TIR): P / N 90357686Exterior Dot-HP RGB, aluminio, frontal direccional ( Lente TIR), juego de 9: P / N 90357698Exterior Dot-HP CW, Aluminio, Transparente Frontal: P / N 90357688Exterior Dot-HP CW, Aluminio, Parte delantera transparente, juego de 9: P / N 90357694Exterior Dot-HP CW, Aluminio, Domo frontal: P / N 90357687Exterior Dot-HP CW, Aluminio, Parte frontal del domo, juego de 9: P / N 90357695Exterior Dot-HP CW, Aluminio, Frente direccional (lente TIR): P / N 90357689Exterior Dot-HP CW, Aluminio, Frente direccional (TIR lente), juego de 9: P / N 90357693